1. Home
  2. Docs
  3. TELLNEXT
  4. Scanner configurations
  5. RS507
  6. RS507 SPP mode
  7. MC33

MC33

Latest recommended config:

_tnx_profile.jcf

"BluetoothSPP": {
  "On": true,
  "Filter": "RS507",
  "PIN": "",
  "UseDeviceMajor": false,
  "UnpairAll": false,
  "DiscoveryOn": false,
  "BarcodeType": "FNC3",
  "ShowUnpairBarcode": false,
  "ScannerType": 6,
  "TerminatorWait": 0,
  "Terminators": ""
},

Tested successfully on:

Android Oreo (8.x)
Manufacturer Device Android Version Date Tnx version Recommended Config
 Notes

Zebra

MC33

8.1.0 19/03/19 Emulator 1.0.9.507
BT Pairing 7.0.3.546
"ScannerType": 6,
  • The test is old, we recommend using Scanner Type 111 (not tested)
  • Sometimes, the first time you pair the scanner, the entire progression bar is consumed and it is necessary to make a second reading of the barcode to pair the scanner successfully.
  • When opening and exiting TellNext several times, the scanner LEDs remain blinking and it is impossible to re-pair. It is required to remove and reinsert the battery.

 

Android Nougat (7.x) – No more tested on this version
Manufacturer Device Android Version Date Tnx version Config deviation / Notes

Zebra

MC33

7.1.2 07/11/18 Emulator 1.0.7.515
BT Pairing 7.0.3.535
"ScannerType": 1,
  • PENDING RE-TEST

 

Recommendations:

  • Some devices are not available for testing, despite this, we recommend the use of Scanner Type 111
  • Use the Filter parameter as much as you can. It will be easier to establish the connection between devices.