Latest recommended config:
_tnx_profile.jcf
"BluetoothSPP": { "On": true, "Filter": "RS507", "PIN": "", "UseDeviceMajor": false, "UnpairAll": false, "DiscoveryOn": false, "BarcodeType": "FNC3", "ShowUnpairBarcode": false, "ScannerType": 2, "TerminatorWait": 0, "Terminators": "" },
Tested successfully on:
Android Oreo (8.x) | |||||
Manufacturer | Device | Android Version | Date | Tnx version | Recommended Config |
Notes | |||||
Zebra | TC51 | 8.1.0 | 24/07/19 |
Emulator 1.0.11.517 |
"ScannerType": 2, |
– The test is old, we recommend using Scanner Type 111 (not tested) – Sometimes it is needed to read the pairing barcode twice with ScannerType 6 |
Android Nougat (7.x) – No more tested on this version | |||||
Manufacturer | Device | Android Version | Date | Tnx version | Config deviation / Notes |
Zebra | TC51 | 7.1.2 | 18/07/19 | Emulator 1.0.11.512 BT Pairing 7.0.3.549 |
"ScannerType": 2 |
– Wait for the second beep when pairing scanner |
Recommendations:
- Some devices are not available for testing, despite this, we recommend the use of Scanner Type 111
- Use the Filter parameter as much as you can. It will be easier to establish the connection between devices.
Scanner Type 111:
- The use of ScannerType: 111 for Zebra devices requires the BT Pairing service at Android Accessibility menu option to be activated. In addition, it is convenient to use UnpairAll: false, to avoid having to scan multiple times to connect the scanner. UnPairAll: true could be more problemathic when you stablish the connection between the device and the scanner.
- Before using the scanner, please, scan the SPP mode and the Non-AutoReconnect barcodes: