1. Home
  2. Docs
  3. TELLNEXT
  4. Scanner configurations
  5. RS507
  6. RS507 SPP mode
  7. EC30

EC30

Latest recommended config:

_tnx_profile.jcf

"BluetoothSPP": {
  "On": true,
  "Filter": "RS507",
  "PIN": "",
  "UseDeviceMajor": false,
  "UnpairAll": false,
  "DiscoveryOn": false,
  "BarcodeType": "FNC3",
  "ShowUnpairBarcode": false,
  "ScannerType": 111,
  "TerminatorWait": 0,
  "Terminators": ""
},

_tnx_application.jcf

"Bluetooth": {
  "OnAtStart": true,
  "OffAtExit": false,
  "KeepPairingOnExit": true,
  "KeepPairingOnStartup": true
}

Tested successfully on:

Android Oreo (8.x)
Manufacturer Device Android Version Date Tnx version Recommended Config
 Notes
Zebra EC30 8.1.0 21/07/20

Emulator 1.0.14.501
BT Pairing 7.0.4.506
Vxt Engine 4.2.5.503
Vxt Calibrate 6.1.2.509

"Filter": "RS507",
"UnpairAll": false,
"ScannerType": 111,
  • Build number 01-23-18.00-OG-U08-STD
  • The first time the scanners are paired, sometimes, it is necessary to read the pairing barcode twice.
  • Scanner reconnected by clicking the Restore Key
  • Voice projects
    • It works with “ScannerType”: 6 (in _tnx_profile.jcf file) -> Used to standardize scanners
    • “HeadsetType”: 1 (in _vxt_configuration.jcf file)
    • “AudioMode”: MODE_NATIVE
    • Headset reconnected successfully
Zebra EC30 8.1.0 16/04/20

Emulator 1.0.13.514
BT Pairing 7.0.4.505
Vxt Engine 4.2.5.502
Vxt Calibrate 6.1.2.507

"Filter": "RS507",
"UnpairAll": false,
"ScannerType": 111,
  • Build number 01-23-18.00-OG-U08-STD
  • The first time the scanners are paired, sometimes, it is necessary to read the pairing barcode twice.
  • Scanner reconnected by clicking the Restore Key
  • Voice projects
    • “HeadsetType”: 1 (in _vxt_configuration.jcf file)
    • “AudioMode”: MODE_NATIVE
    • Headset reconnected successfully
Zebra EC30 8.1.0 06/03/20 Emulator 1.0.13.510
BT Pairing 7.0.4.504
"UnpairAll": false,
"ScannerType": 111,
  • The first time the scanners are paired, it is necessary to read the pairing barcode twice.
  • Scanner reconnected by clicking the Restore Key
  • Pending test with headset

 

Android Nougat (7.x) – No more tested on this version
Manufacturer Device Android Version Date Tnx version Config deviation / Notes
           

 

 

Recommendations:

  • Use the Filter parameter as much as you can. It will be easier to establish the connection between devices.

 

 

Scanner Type 111:

  • The use of ScannerType: 111 for Zebra devices requires the BT Pairing service at Android Accessibility menu option to be activated. In addition, it is convenient to use UnpairAll: false, to avoid having to scan multiple times to connect the scanner. UnPairAll: true could be more problemathic when you stablish the connection between the device and the scanner.
  • Before using the scanner, please, scan the SPP mode and the Non-AutoReconnect barcodes: